Johnstech

Leaded ROL™200KR Kelvin-Ready

Test Socket/Test Contactor*

* Specifications for Force Contact shown

Electrical Specifications

Matte Tin Configuration

NiPdAu Configuration

Electrical Length:

1.98 mm

2.00 mm

Inductance:

Self: 0.46 nH
Mutual: 0.04 nH

Self: 0.46 nH
Mutual: 0.03 nH

Capacitance

Ground: 0.10 pF
Mutual: 0.02 pF

Ground: 0.10 pF
Mutual: 0.02 pF

S21 (Insertion Loss/Bandwidth):

-1 dB @ 23.3 GHz

-1 dB @ 23.1 GHz

S11 (Return Loss/Bandwidth):

-20 dB @ 8.2 GHz

-20 dB @ 9.4 GHz

S41 (Crosstalk/
bandwidth):

-20 dB @ 34.7 GHz

-20 dB @ 29.9 GHz

Contact DC Resistance:

60 mohm

30 mohm

Current Carrying Capability:

2.75 A Force

1.25 A Sense

3.55 A Force

1.25 A Sense

Current Leakage:

<1 pA @ 10 V

<1 pA @ 10 V

Nearest Decoupling Area:

1.80 mm

1.80 mm

Mechanical Specifications

Matte Tin Configuration

NiPdAu Configuration

Contact Force (per Contact): 60 grams 30 grams
Physical Contact Length: 2.58 mm 2.59 mm
Physical Compressed Height: 1.34 mm 1.34 mm

Typical Contactor Life (# Insertions):

Elastomers = 300,000 
Force Contacts = 500,000+ (matte tin) 
Force Contacts =  500,000+   (NiPdAu)
Sense Contacts = 1,000,000

Housing = 2,000,000

Contact Compliance 0.20 mm 0.20 mm
Contact Wipe on Lead: 0.22 mm 0.13 mm
Contact Tip Coplanarity: 0.05 mm 0.05 mm

Environment:

-40°C to 155°C

Housing Material:

Torlon® 5030

Contacts:

Gold-plated XL-2K Fine Tip

Leaded ROL™200KR Methodology




Manual Actuator

VMA (Vertical Manual Actuator)
ZMA (Z-Axis Manual Actuator)


Housing Options

Housings are offered in standard handler-specific sizes with custom sizes also available. Contact Johnstech for assistance.


Grounding Options

RTH- ROL™ Contacts in Torlon® Housing
RCI- ROL™ Contacts in Copper Insert


Johnstech Services/Resources

Test Floor Technical Support Worldwide Field Service Offices;
First-Pass Yield Enhancement; Performance Audits; Customized Training and Applications Engineering.
Online Tech Support Form at: www.johnstechhelp.com

Engineering Services – Load Board Evaluation & Testing; HFSS 3D Modeling; Electrical Performance Analysis; PCB/Contactor/Device Optimization; Contactor S Parameter & Characterization Data; Thermal Conductivity Analysis and Advanced Design System (ADS) Simulation, Analysis & Optimization.

Website  – Product, Test, Industry and Support Information; Downloadable, Product SpecSheets; Maintenance & Inspection Guides, Tech Papers and Application Notes.

Your Contact for Higher Performance