Download Spec Sheet
Download Maintenance & Inspection Guide
Leaded ROL™400 Series Methodology Model - Eco™-1 Contact

Leaded ROL™400 Series Methodology Model - Gold-Plated Contact

| Electrical Specifications | Gold-Plated |
Eco™-1 |
Electrical Length (compressed height): |
3.53 mm |
3.58 mm |
Inductance: |
Self: 0.75 nH |
Self: 0.74 nH |
Capacitance |
Ground: 0.83 pF |
Ground: 0.80 pF |
S21 (Insertion Loss/Bandwidth): |
-1 dB @ 5.6 GHz |
-1 dB @ 5.4 GHz |
S11 (Return Loss/Bandwidth): |
-20 dB @ 1.6 GHz |
-20 dB @ 1.6 GHz |
Crosstalk/bandwidth: |
-20 dB @ 4.0 GHz |
-20 dB @ 4.6 GHz |
Contact DC Resistance: |
<29 m |
<9 m |
Current Carrying Capability: |
5.70 A |
5.30 A |
Current Leakage: |
<1 pA @ 10 V |
<1 pA @ 10 V |
Nearest Decoupling Area: |
1.80 mm |
1.80 mm |
Mechanical Specifications |
Gold-Plated |
Eco™-1 |
Physical Contact Length: |
4.55 mm |
4.55 mm |
Physical Compressed Height: |
2.79 mm |
2.79 mm |
Typical Contactor Life ( # Insertions): |
Elastomers = 300,000 |
Elastomers = 300,000 |
Contact Compliance |
0.23 mm |
0.23 mm |
Contact Wipe on Lead: |
0.25 mm |
0.25 mm |
Contact Force: |
70 grams |
30 grams |
Contact Tip Coplanarity |
0.05 mm |
0.05 mm |
Environment: |
-40°C to 155°C |
-40°C to 155°C |
Housing Material: |
Torlon® 5030 |
Torlon® 5030 |
Contact Material: |
BeCuNiAu |
Eco™-1 |
Note: Depending on Interface Numbers May Vary |
Results from Matte Tin Device Test, 0.5mm pitch |
Results from NiPdAU Device Test, 0.5mm pitch. |
Manual Actuator
VMA (Vertical Manual Actuator)
ZMA (Z-axis Manual Actuator)
Choice is dependent on Housing size and configuration.
Housing Options
Housings are offered in standard handler-specific sizes with custom sizes also available. Contact Johnstech for assistance.
RTH- ROL™ Contacts in Torlon Housing
Other Johnstech Services/Resource Options
Test Floor Technical Support – Worldwide Field Service Offices;
First-Pass Yield Enhancement; Performance Audits; Customized Training and Applications Engineering.
Online Tech Support Form at: www.johnstechhelp.com
Engineering Services – Load Board Evaluation & Testing; HFSS 3D Modeling; Electrical Performance Analysis; PCB/Contactor/Device Optimization; Contactor S Parameter & Characterization Data; Thermal Conductivity Analysis; Advanced Design System (ADS) Simulation, Analysis & Optimization.
Website (www.johnstech.com) – Product, Test, Industry and Support Information; Downloadable, Product SpecSheets; Maintenance & Inspection Guides, Tech Papers and Application Notes.