Download Spec Sheet
Download Maintenance & Inspection Guide
Pad Series 2mm Methodology

Johnstech Pad Series 2mm Test Contactors
For QFN, DFN, BCC++, and LCC Pad-Style Applications
| Electrical Specifications | Gold-Plated Contact |
Electrical Length (compressed height): |
2.14 mm |
Inductance:1 |
Self: 0.50 nH |
Capacitance:1 |
Ground: 0.50 pF |
S21 (Insertion Loss/Bandwidth):2 |
-1 dB @ 11 GHz |
S11 (Return Loss):2 |
-20 dB @ 9 GHz |
S41 Crosstalk: |
<20 m |
Contact DC Resistance:3 |
-20 dB @ 14 GHz |
Current Carrying Capability:4 |
5.20 A |
Current Leakage: |
<1 pA @ 10V |
Mechanical Specifications |
|
Physical Contact Length: |
2.35 mm |
Physical Compressed Height: |
1.40 mm |
Contactor Life (# of insertions): |
Elastomers = 100,000 to 500.000 |
Contact Compliance |
0.20 mm |
Contact Wipe on Pad: |
0.10 - 0.15 mm |
Contact Force: |
45-60 grams |
Contact Tip Coplanarity: |
0.05 mm |
Environment: |
-40°C to 155°C |
Housing Material: |
Torlon® 5030 |
Contact Material: |
BeCuNiAu |
Depending on interface, numbers may vary. Specifications subject to change. |
Based on 0.50 mm pitch. |
Manual Actuator
Both Double-Latch (DL-VCMA) and Single-Latch (SL-VCMA) Vertically
Compliant Manual Actuators are available. The SL-VCMA is only available for certain configurations.
Manual Actuator Material: Ultem®
Housing Options
Housings are offered in standard handler specific sizes, with custom sizes also available. Contact Johnstech for assistance.
Contact Options
Gold-Plated
Full Tip or Fine Tip
Pitches 0.4mm - 1.27mm
EI - Eco™-1 Insert (3x3 & 4x4 package sizes)
STH- S Contacts in Housing
SCI- S Contacts in Copper Insert
CI- Solid Copper Insert
Other Johnstech Services/Resource Options
Test Floor Technical Support – Worldwide Field Service Offices;
First-Pass Yield Enhancement; Performance Audits; Customized Training; Applications Engineering;
Online Tech Support Form at: www.johnstechhelp.com
Engineering Services – Load Board Evaluation & Testing; HFSS 3D Modeling; Electrical Performance Analysis; PCB/Contactor/Device Optimization; Contactor S Parameter & Characterization Data; Thermal Conductivity Analysis; Advanced Design System (ADS) Simulation, Analysis & Optimization
Website (www.johnstech.com) – Product, Test, Industry and Support Information; Downloadable, Product SpecSheets; Maintenance & Inspection Guides, Tech Papers, Application Notes;